(For USM Staff/Student Only)

EngLib USM > Ω School of Electrical & Electronic Engineering >

Development of radiation dosimeter/Jeffery Kong Soon Jye

Development of radiation dosimeter_Jeffery Kong Soon Jye_E3_2013_NI
Pengesan radioaktif digunakan secara meluas kerana kemunculan sinaran mengion dalam alam sekitar. Dua pengesan telah dibina iaitu "ionization chamber" dan "optically stimulated luminescence dosimeter" (OSLD). Objektif untuk membina kedua-dua pengesan radioaktif adalah untuk membandingkan prestasi, kebolehpercayaan dan efektif kos. Dalam pembinaan "ionization chamber", Americium241 telah digunakan sebagai sumber radioaktif. Dua parameter telah dipakai untuk mengumpul data. Data itu digunakan untuk membuat analisis dan keputusan dibandingkan dengan keputusan kerja lalu. Kedua-dua parameters adalah jarak antara pengesan radioaktif dan sumber radioaktif dan bekalan kuasa digunakan oleh pengesan. Dalam pembinaan OSLD, Yttrium tantalate, (YTaO4) telah digunakan sebagai sumber OSL, Americium-241 diguna sebagai sumber rangsangan, OPT101 diguna sebagai pengesan foto, Atmega32A diguna sebagai mikropemproses dan UC00A diguna sebagai penukar UART-USB. Barangan ini berhimpun bersama untuk menjadi OSLD. Satu parameter telah digunakan untuk memeriksa OSLD iaitu jarak antara pengesan dengan sumber. Ionization chamberdan OSLD telah berjaya dibina dalam projek ini. Ionization chamber memberi keputusan yang bagus. Walaubagaimanapun, OSLD tidak menjalani percubaan kerana ketiadaan sumber OSL. Oleh itu, projek ini akan disambungkan oleh penyelidik lain untuk mencapai objektif projek ini. ___________________________________________________________________________________ Radioactive detector is used widely due to the existing of ionizing radiation in the environment. Two dosimeters are implemented which are ionization chamber and optically stimulated luminescence dosimeter (OSLD). The objectives of implement these two dosimeters are to compare the performance, reliability and cost effective among them and found out the one that can compete with commercial ones. For ionization chamber, Americium-241 is used as radioactive source. Two parameters are used to collect the data in order to do analysis and compare the result with the past work. The parameters are source-to-detector distance and applied power supply. For OSLD, Yttrium Tantalate, (YTaO4) used as OSL material, Americuium-241 used as stimulation source, OPT101 used as photo sensor, Atmega32A used as microprocessor and UC00A used as UART-to-USB Converter. Those things will assemble together to become OSLD. One parameter is used to examine the OSLD which is source-todetector distance. In the end, Ionization chamber and OSLD are successfully built. Ionization chamber is expected operate correctly as the one in commercial. However, OSLD cannot ensure to work correctly due to the absence of OSL material. Therefore, experiment cannot be done on it and the research will continue by other researcher in order to fulfill the objectives of this project.
Contributor(s):
Jeffery Kong Soon Jye - Author
Primary Item Type:
Final Year Project
Language:
English
Subject Keywords:
radioactive ; chamber ; ionization
First presented to the public:
6/1/2013
Original Publication Date:
2/13/2020
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Electrical & Electronic Engineering
Citation:
Extents:
Number of Pages - 81
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2020-02-14 10:47:40.466
Submitter:
Nor Hayati Ismail

All Versions

Thumbnail Name Version Created Date
Development of radiation dosimeter/Jeffery Kong Soon Jye1 2020-02-14 10:47:40.466