BS EN 61660-2:1997 - Short-circuit currents in d.c. auxiliary installations in power plants and substations - Part 2. Calculation of effects

Printed version of this is available at library. To request, please e-mail to referencepk@usm.my and include a copy of this record in your e-mail.
This part of IEC 61660 describes a method for calculation of the mechanical and thermal effects on rigid conductors caused by short-circuit currents in d.c. auxiliary installations in power plants and substations. Such systems may contain the following items of equipment which act as sources, as well as contributing to the short-circuit currents: - rectifiers in three-phase a.c. bridge connection for 50 Hz; - stationary lead-acid batteries; - smoothing capacitors; - d.c. motors with independent excitation. This standard provides a method which has wide application, and which gives results of sufficient accuracy. The calculation method is based on substitute functions, which cause approximately the same maximum stresses in the conductors and the same forces on the supports as the actual electromagnetic force. The standardized calculation procedures of clauses 2 and 3 are applicable for the electromagnetic effect on rigid conductors and the thermal effect on bare conductors and electrical equipment, respectively. For cables and insulated conductors, however, reference is made to IEC 60949 and IEC 60986, for example. Only d.c. auxiliary installations in power plants and substations are dealt with in this standard. n particular, the following points should be noted: - The calculation of short-circuit currents should be based on IEC 61660-1. - Short-circuit duration used in this standard depends on the protection concept, and should be considered in that sense. - These standardized procedures are adjusted to practical requirements, and contain simplifications with safety margins. Testing or more detailed methods of calculation or both may be used. - In clause 2 of this standard, only the stresses caused by short-circuit currents are calculated. Furthermore, other stresses can exist, such as those caused by dead-load, operating forces, or earthquakes. The combination of these loads with the short-circuit loading should be part of an agreement and/or given by standards, for example erection codes.
Contributor(s):
ESAR - Data Entry Person
Primary Item Type:
British Standard
Identifiers:
ICS 29.240.01 Power transmission and distribution networks in general
ISBN 0 580 28530 8
Language:
English
Subject Keywords:
Thermal properties of materials; Rigid conductors; Direct-current generators; Electric power transmission; Equations; Electric field effects; Electric substations; Direct current; Electrical equipment; Electric power stations; Mathematical calculations; Graphical methods; Direct-current power transmission; Electric conductors; Short-circuit currents; Force; Frequencies; Electrical installations; Non-insulated wires
First presented to the public:
3/18/2026
Original Publication Date:
10/15/1997
Previously Published By:
British Standards Institution
Place Of Publication:
London, United Kingdom
Citation:
Extents:
Number of Pages - 39
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2026-03-18 15:43:21.555
Submitter:
Engku Shahidil Engku Ab Rahman

All Versions

Thumbnail Name Version Created Date
BS EN 61660-2:1997 - Short-circuit currents in d.c. auxiliary installations in power plants and substations - Part 2. Calculation of effects1 2026-03-18 15:43:21.555