(For USM Staff/Student Only)

EngLib USM > Ω School of Civil Engineering >

The effect of sewage sludge ash as cement replacement material on the mechanical and chemical properties of mortar concrete and terrazzo tiles / Mohamad Nazli Md Jamil

The effect of sewage sludge ash as cement replacement material on the mechanical and chemical properties of mortar concrete and terrazzo tiles_Mohamad Nazli Md Jamil_A9_2017_MYMY
Kumbahan enapcemar adalah hasil pembuangan dari loji rawatan air sisa. Pada masa kini, penghasilan kumbahan enapcemar dalam kuantiti besar diterajui oleh pembangunan pesat loji rawatan kumbahan. Jumlah enapcemar yang besar ini dihasilkan secara berterusan dan menyebabkan pengehadan dalam kawasan pelupusan. Oleh itu, langkah alternatif perlu dilakukan untuk mengguna semula kumbahan enapcemar sebagai pembangunan lestari. Objektif utama dalam kajian penyelidikan ini adalah untuk menggunakan kumbahan enapcemar sebagai bahan tambah semulajadi dalam jubin terazo. Abu kumbahan enapcemar (SSA) dihasilkan daripada proses pengeringan dan pengisaran. Suhu pembakaran optimum SSA ditentukan daripada pembakaran SSA dengan suhu yang berbeza iaitu dari 500 - 1000oC dengan selaan 100oC setiap satu dan dibancuh sebagai mortar. Ciri-ciri fizikal dan kimia setiap mortar telah diuji. Dengan mempertimbangkan keputusan daripada ujian-ujian tersebut, SSA dengan suhu pembakaran 900oC (SSA900) dipilih sebagai suhu pembakaran optima. Kemudian, campuran konkrit dibancuh dengan berbeza peratus penggantian SSA900 untuk menentukan jumlah peratusan yang ideal. Sifat-sifat kejuruteraan dan kepekatan logam berat juga diuji. Hasil daripada ujian yang dijalankan, konkrit dengan peratusan penggantian SSA900 sebanyak 15% dipilih sebagai peratusan penggantian ideal kerana ia menunjukkan hasil yang positif. Prestasi jubin terazo SSA telah diperiksa dengan menguji mereka dengan kekuatan pecah, penyerapan air dan rintangan gelinciran bagi penggantian 0, 5, 10, 15 dan 20%. Menurut MS 738: 1981, kekuatan minimum bagi jubin terrazzo adalah 3.0 MPa, kadar penyerapan kapilari dan penyerapan total haruslah tidak melebihi 0.4 g/cm2 dan 8% masing-masing. Kadar gelinciran jubin terrazzo ini juga telah diklasifikasikan sebagai amat rendah oleh United Kingdom Slip Resistance Group (UKSRG, 2011). __________________________________________________________________________________ Sewage sludge is a residual from wastewater treatment plant. Nowadays, the large production in sewage sludge quantity is led by the rapid development of sewage treatment plant. This large amount of sewage sludge is generated continuously and has caused in limitation of the disposal area. Hence, an alternative way must be sought out to reuse the sewage sludge for sustainable development. The main objective of this study is to utilize the sewage sludge as a natural admixture in terrazzo tile application. The sewage sludge ash (SSA) was produced by drying and ball-milling process. The optimum incineration temperature of SSA was determined by incinerating the SSA at varying temperature ranging from 500 – 1000oC an with interval of 100oC respectively and mixed as mortar. The physical and chemical properties of each mortar were tested. From the results of the tests, the incinerated temperature of SSA at 900oC (SSA900) was chosen as optimum incineration temperature. Then, concrete mixture with the replacement of SSA900 was casted to determine the ideal percentage amount. The engineering properties and heavy metal concentration were tested. As a result, the concrete with 15% of SSA900 replacement was chosen as an ideal percentage of replacement because it showed the positive outcome for the most of the tests. The performance of SSA terrazzo tiles were examined by testing on breaking strength, water absorption and skid resistance for replacement of 0, 5, 10, 15 and 20%. According to MS 738:1981, the minimum breaking strength is 3.0 MPa, the capillary and total absorption must not exceed of 0.4 g/cm2 and 8% respectively. The terrazzo tile specimens passed the standard requirement. Plus, the tiles were also classified as extremely low in slip potential as compared to United Kingdom Slip Resistance Group (USRG, 2011).
Contributor(s):
Mohamad Nazli Md Jamil - Author
Primary Item Type:
Thesis
Identifiers:
Accession Number : 875008751
Language:
English
Subject Keywords:
sewage; admixture; incineration
Sponsor - Description:
Pusat pengajian Kejuruteraan Awam -
Originally created:
4/1/2017
Original Publication Date:
3/10/2020
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Civil Engineering
Citation:
Extents:
Number of Pages - 140
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2020-03-10 12:09:38.777
Date Last Updated
2020-12-03 15:45:34.742
Submitter:
Mohamed Yunus Yusof

All Versions

Thumbnail Name Version Created Date
The effect of sewage sludge ash as cement replacement material on the mechanical and chemical properties of mortar concrete and terrazzo tiles / Mohamad Nazli Md Jamil1 2020-03-10 12:09:38.777