BS EN 61046:1995 Specification for d.c. or a.c. supplied electronic step-down convertors for filament lamps. General and safety requirements
Withdrawn
Printed version of this is available at library. To request, please e-mail to referencepk@usm.my and include a copy of this record in your e-mail.
This International Standard specifies general and safety requirements for electronic stepdown convertors for use on d.c. supplies up to 250 V or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz and rated output voltage ≤50 V r.m.s. at a frequency deviating from the supply frequency or <50 √2 V unsmoothed d.c. between conductors or between any conductor and earth, associated with tungsten-halogen lamps as specified in IEC 357 and other filament lamps.
NOTE- The limit of 50 V rated output voltage is in accordance with Band I of IEC 449.
Particular requirements for electronic step-down convertors with means of protection against overheating are given in annex B.
Particular requirements for stationary independent SELV convertors, which are part of the wiring in installations, are given in annex C.
Plug-in convertors, being part of the luminaire, are covered as built-in convertors together with the additional requirements of the luminaire standard.
NOTE- These proposals have also been submitted to SC 14D for introduction in the new omnibus standard IEC 742 which is in preparation.