Automatic circuit breaker (acb) for low voltage substation distribution system

Automatic circuit breaker (acb) for low voltage substation distribution system / Norazizah Norhafazid
Pemutus Litar Automatik (PLA) adalah peranti yang menghalang gangguan arus dalam rangkaian bekalan kuasa, terutamanya melalui litar pintas. Gangguan arka terbentuk semasa pemisahan hubungan pada arus tinggi. Pada laluan sifar, kesalahan, arka diganggu pada mulanya. Voltan pemulihan sementara (TRV) memulihkan tekanan dielektrik yang tinggi dari rangkaian. Dengan menggunakan kaedah salutan sekatan semasa (CLFs), penggunaan arus yang berlebihan dapat menghadkan masa penjelasan pada voltan dengan mudah yang mempunyai nilai yang sama atau kurang daripada tempoh gelung utama atau simetrik pertama dan juga mengehadkan arus puncak kepada suatu nilai kurang daripada arus puncak yang ada. Dua jenis model pemutus digunakan dalam reka bentuk simulasi untuk membandingkan graf I-V. Pengganti pelindung digunakan dalam reka bentuk untuk mengesan dan mengenal pasti kesalahan serta menentukan bila litar perlu dibuka. Sistem ini disimulasikan dalam satu keadaan dengan menggunakan dua jenis model pemutus dan kesannya diperhatikan. Keputusan menunjukkan bahawa arus berlebihan akan diputuskan secara automatik. Pemutus arus dan pemutus voltan menunjukkan bahawa keputusan memberi kesan yang baik selepas sistem ini dijalankan dimana ia meningkat dari 30% hingga 60%. Analisis dan penilaian pemutus litar automatic menunjukkan bahawa system ini dapat mengurangkan penggunaan arus berlebihan dan berpotensi untuk menghalang pembaziran penggunaan tenaga elektrik. _______________________________________________________________________________________________________ An Automatic Circuit Breaker (ACB) is a device that interrupts fault currents in power supply networks, mainly through short circuits. Current interruption of the high current arc is formed by extinction upon contact separation. At fault current zero passage, an arc is initially interrupted. The transient recovery voltage (TRV) recovering contact gap is heavily stressed dielectrically from the network. By using current-limiting fuses (CLFs) method, the usage of the overcurrent can be easy limits the clearing time at rated voltage to an interval equal to or less than the first major or symmetrical current loop duration and also limits the peak current to a value less than the available peak current. Two types of breaker model used in the simulation design to compare the I-V graph. The protective relay used in the design to detect and evaluate the fault and determines when the circuit should be opened. The system is simulated in one condition by using two types of breaker model and effects are observed. The results show that the current will automatically cut the overcurrent. The breaker current and breaker voltage show that the result gives a good impact after this system has run which is increases from 30% to 60%. Analysis and the evaluation of the automatic circuit breaker shown that this system can be able to cut the overcurrent limit and has the potential to prevent the usage of electric energy due to fault occurs.
Contributor(s):
Norazizah Norhafazid - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875008731
Language:
English
Subject Keywords:
(ACB); currents; (CLFs)
First presented to the public:
6/1/2019
Original Publication Date:
3/11/2020
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Electrical & Electronic Engineering
Citation:
Extents:
Number of Pages - 63
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2020-03-11 15:02:20.616
Date Last Updated
2020-12-02 11:57:45.173
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Automatic circuit breaker (acb) for low voltage substation distribution system1 2020-03-11 15:02:20.616