(For USM Staff/Student Only)

EngLib USM > Ω School of Civil Engineering >

Radial gate hydraulic modelling of Sultan Abu Bakar DAM, Cameron Highland

Radial gate hydraulic modelling of Sultan Abu Bakar DAM, Cameron Highland / Anuar Effendy Mat Lani
Objektif utama kajian ini adalah untuk menentukan pekali kadar aliran dan untuk membangunkan lengkung pengkadaran untuk satu pintu, gabungan dua pintu dan semua pintu jejari daripada Empangan Sultan Abu Bakar, Cameron Highland, Pahang. Model fizikal empangan Sultan Abu Bakar telah dihasilkan seperti model yang sedia ada dengan skala mendatar 1 nisbah 25 (model:prototaip) dan skala menegak 1 nisbah 25(model:prototaip). Perkakas yang digunakan semasa proses ujian ialah “Nixon Streamflo Velocity Meter” dan “Ultrasonic Flow Meter”. “Nixon Streamflo Velocity Meter” boleh mengukur halaju air daripada bukaan pintu jejari manakala “Ultrasonic Flow Meter” boleh mengukur kadar alir daripada paip semasa model fizikal sedang berfungsi. Untuk mengetahui ketepatan perkakas ujian, ujian penentukuran telah dilakukan sebelum digunakan semasa proses ujian ke atas model fizikal. Hasil daripada proses ujian menunjukkan pekali kadar aliran dan hubungan antara kadar alir (𝑚3/s) dengan takungan kepala hulu (mm) di pembukaan pintu jejari yang berbeza. Dari ujian model fizikal tersebut pekali kadar alir bagi pintu jejari adalah diantara 0.75-0.84. Selain itu, untuk skala penuh model fizikal untuk bukaan 0.5m, 0.65m, 0.5m untuk semua pintu jejari adalah 239 m3/s. Proses ini dapat membantu TNB dalam proses pelepasan air dari SAB Dam bagi mengelakkan banjir berlaku. _______________________________________________________________________________________________________ The main objective for this study is to determine discharge coefficient and to developed a discharged rating curve for individual gate, combination of two gates and all radial gates from physical model of Sultan Abu Bakar Dam, Cameron Highland, Pahang. The physical model of Sultan Abu Bakar Dam was produced as a normal model with a horizontal scale of 1/25 and a vertical scale of 1/25. The equipment that are used during testing process are Nixon Streamflo Velocity Meter and Ultrasonic Flow Meter. Nixon Streamflo Velocity Meter can measure the velocity of water from the opening of the radial gate while Ultrasonic Flow Meter can measure the discharged from the pipe during the physical model was running. To know the accuracy of this testing equipment, the calibration testing was done before use it during the testing process on physical model. The result from the testing process show the discharge coefficient and the relationship of discharge (m3/s) with the upstream head (mm) of reservoir at difference opening of the radial gate. From this physical model testing, discharge coefficient (Cd) from all radial gates are between 0.75-0.84. Besides that, for the full-scale physical model, opening of 0.5m, 0.65m, 0.5m for all radial gate show the highest discharge which is 417 m3/s. This will help TNB in process to release water from SAB Dam to avoid occurrence of flooding.
Contributor(s):
Anuar Effendy Mat Lani - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875006808
Barcode : 000003106685
Language:
English
Subject Keywords:
discharge coefficient; Nixon Streamflo Velocity Meter; Ultrasonic Flow Meter
First presented to the public:
6/1/2017
Original Publication Date:
3/22/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Civil Engineering
Citation:
Extents:
Number of Pages - 98
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-03-22 10:20:29.858
Date Last Updated
2020-06-01 11:49:38.989
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Radial gate hydraulic modelling of Sultan Abu Bakar DAM, Cameron Highland1 2018-03-22 10:20:29.858