MS IEC 62353:2013 Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment (IEC 62353:2007, IDT)

MS IEC 62353:2013 Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment (IEC 62353:2007, IDT)
Printed version of this standard is available at Library. To request, please e-mail to adminpk@usm.my and include a copy of this record in your e-mail.
This Malaysian Standard applies to testing of medical electrical equipment and medical electrical systems, hereafter referred to as ME equipment and ME systems, or parts of such equipment or systems, which comply with MS IEC 60601-1, before putting into service, during maintenance, inspection, servicing and after repair or on occasion of recurrent tests to assess the safety of such ME equipment or ME systems or parts thereof. For equipment not built to MS IEC 60601-1 these requirements may be used taking into account the safety standards for the design and information in the instructions for use of that equipment. This Malaysian Standard contains tables with allowable values relating to different editions of MS IEC 60601-1. For the purpose of this standard, the application of measuring methods is independent of the edition according to which the ME equipment or ME system is designed. This Malaysian Standard contains: - general requirements", which contain clauses of general concern, and - particular requirements", further clauses handling special types of ME equipment or ME systems and applying in connection with the "general requirements". This Malaysian Standard is not suitable to assess whether ME equipment or ME systems or any other equipment comply with the relevant standards for their design. This standard does not define requirements for repair, exchange of components and modification of ME equipment or ME systems. This Malaysian Standard is also applicable to tests after repair. The testing shall be defined according to the extent of work performed and applicable guidance from the manufacturer. This Malaysian Standard is not intended to define time intervals for recurrent tests. If such intervals are not defined by the manufacturer, Annex F may be used to help establish such intervals.
Primary Item Type:
Malaysian Standard
Identifiers:
ICS 11.040
Standard Number MS IEC 62353:2013
ISC ISC R - Medical Devices and Facilities for Healthcare
Language:
English
Subject Keywords:
Medical electrical equipment
First presented to the public:
6/20/2018
Original Publication Date:
6/4/2013
Previously Published By:
Department of Standards Malaysia
Place Of Publication:
Cyberjaya, Selangor
Citation:
Extents:
Note - Correspondence to International Standard: IEC 62353:2007, Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment
Number of Pages - 53
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-06-20 12:31:21.285
Date Last Updated
2019-01-07 11:24:16.6254
Submitter:
Mazainun Aini Mohd Zain

All Versions

Thumbnail Name Version Created Date
MS IEC 62353:2013 Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment (IEC 62353:2007, IDT)1 2018-06-20 12:31:21.285