(For USM Staff/Student Only)

EngLib USM > Ω School of Civil Engineering >

Effect of silica fume inclusion on properties of high strength concrete containing high volume of steel slag

Effect of silica fume inclusion on properties of high strength concrete containing high volume of steel slag / Mohammad Nazeem Mohsin
Pengunnan tanah granulated relast slag konkrit adalah berfaedah dari pandangan ekonomi, alam sekitar dan teknikal. untuk menghancurkan gerek letupan konkrit dalam konkrit adalah berfaedah dari pandangan ekonomi, alam sekitar dan teknikal. Walau bagaimanapun, penggunaan sanga terutamanya dalam jumlah tinggi boleh menjejaskan kekuatan dan sifat konkrit lain. Oleh itu, kajian ini meneroka kemungkinan menggunakan wasap silika sebagai penggantian sebahagian daripada sanga dalam konkrit kekuatan tinggi yang mengandungi jumlah isipadu yang tinggi. Campuran konkrit berkekuatan tinggi dengan kekuatan 28 hari sebanyak 70 MPa. Campuran yang serupa adalah sebanding tetapi 60% daripada simen Portland biasa diganti dengan sanga secara massal untuk massa. Tambahan pula, empat campuran konkrit lain pula dipengaruhi oleh sebahagiannya menggantikan kandungan sanga dengan wasap silika pada 5, 10, 15 dan 20%. Kesan penggabungan sanga pada kebolehkerjaan, ketumpatan, kekuatan mampatan, keliangan dan penyerapan air konkrit telah diselidiki. Keputusan menunjukkan bahawa penggunaan sanga dalam kombinasi dengan wasap silika cenderung untuk mengurangkan kebolehkerjaan konkrit kekuatan tinggi. Campuran konkrit yang mengandungi sanga serta kombinasi sanga dan silika mempamerkan kepadatan yang lebih tinggi daripada konkrit kawalan. Kemasukan wasap silika meningkatkan kekuatan konkrit berkekuatan tinggi yang mengandungi isipadu tinggi sanga, khususnya kandungan wasap silika yang lebih tinggi, tetapi kekuatan yang diperoleh tidak melebihi campuran konkrit kawalan. Pengaruh kemasukan silika ke atas keliangan dan penyerapan air konkrit kekuatan tinggi yang mengandungi isipadu tinggi sanga adalah dengan ketara mengurangkan kedua-dua keliangan dan penyerapan air khususnya pada kandungan isian silika yang lebih tinggi dan tempoh pengawetan yang lebih lama. Keputusan menunjukkan bahawa konkrit yang mengandungi 20% wasap silika mencatatkan nilai kemerosotan 13 mm, dengan ketumpatan 2544 kg / m3, kekuatan mampatan 76.03 MPa, keliangan 5.29% dan penyerapan air 3.23% pada usia 56 hari. _______________________________________________________________________________________________________ The use ground granulated blast furnace slag in concrete is advantageous from economic, environmental and technical points of view. However, the use of slag especially in high volume may negatively affect the strength and other properties of concrete. Therefore, this study explores the feasibility of using silica fume as partial replacement of slag in high strength concrete containing high volume of slag. A control high strength concrete mix was proportioned to have a 28 days strength of 70 MPa. A similar mix was proportioned but 60% of the ordinary Portland cement was replaced with slag on mass-for-mass basis. Further, another four concrete mixes were proportioned by partially replacing the slag content with silica fume at 5, 10, 15 and 20%. The effects of the incorporation of silica fume on workability, density, compressive strength, porosity and water absorption of the concrete were investigated. The results exhibit that the use of slag in combination with silica fume tends to reduce the workability of the high strength concrete. Concrete mixes containing slag as well as combination of slag and silica fume exhibit higher density than the control concrete. The inclusion of silica fume improves the strength of the high strength concrete containing high volume of slag, in particular at higher silica fume content, but the strength obtained does not exceed that of the control concrete mix. The influence of silica fume inclusion on porosity and water absorption of the high strength concrete containing high volume of slag is to significantly reduce both porosity and water absorption in particular at higher silica fume content and longer curing period. The results show that concrete containing 20% silica fume registers a slump value of 13 mm, with density of 2544 kg/m3, compressive strength of 76.03 MPa, porosity of 5.29% and water absorption of 3.23% at the age of 56 days.
Contributor(s):
Mohammad Nazeem Mohsin - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875007601
Language:
English
Subject Keywords:
ground; slag; concrete
First presented to the public:
6/1/2018
Original Publication Date:
8/3/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Chemical Engineering
Citation:
Extents:
Number of Pages - 62
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-08-03 16:30:46.259
Date Last Updated
2020-05-23 00:32:02.262
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Effect of silica fume inclusion on properties of high strength concrete containing high volume of steel slag1 2018-08-03 16:30:46.259