(For USM Staff/Student Only)

EngLib USM > Ω School of Electrical & Electronic Engineering >

Rogowski coil sensor for partial discharge Detection

Rogowski coil sensor for partial discharge Detection / Puovin Murugaiah
Istilah nyahcaj merujuk kepada ancaman yang boleh menyebabkan kelesuan pada penebatnya di zon medan elektrik yang sangat tinggi. Oleh itu, untuk mengelakkan kelesuan berlaku, pemerhatian yang kerap dilakukan dengan menggunakan kaedah pengesanan yang tepat. Pengukuran nyahcaj jenis ini adalah penting kerana kewujudannya berkaitan dengan penuaan penebat dalam peralatan elektrik. Pengukuran PD biasanya digunakan untuk menilai kualiti penebat peralatan voltan tinggi. Terdapat banyak alat pengesan PD yang ada di pasaran, dan pengesan menggunakan banyak teknik yang berbeza dalam mengukur PD. Makalah ini membentangkan sistem pengesanan PD peranti mudah alih dan kos rendah dengan penggunaan gegelung Rogowski (RC). Kekerapan frekuensi tinggi kerana PD dikesan oleh RC. RC dibangunkan untuk julat frekuensi tinggi dari satu MHz sehingga pesanan seratus MHz. Analisis eksperimen dilakukan untuk menilai prestasi gegelung Rogowski dan kesan litar yang dirancang pada bentuk gelombang RC untuk pengesanan PD. Eksperimen diatur dalam makmal voltan tinggi. Ujian dijalankan mengenai keadaan pengukuran seperti sistem pengukur PD dalam talian. Isyarat PD yang dijana oleh penjana pulse dilalukan melalui pusat RC di mana keluarannya telah disambungkan ke litar yang dirancang. Pengukuran dibuat dengan menggunakan osiloskop untuk mendapatkan bentuk gelombang yang dihasil. Reka bentuk litar dilakukan untuk meningkatkan output RC untuk sistem pengesanan yang lebih baik serta mendapatkan isyarat yang mereplikasi isyarat PD sebenar. Daripada eksperimen ini disiasat bahawa kaedah pengesanan RC ini berfungsi secara linear dan dengan kepekaan tinggi ke input terendah (5pC). _______________________________________________________________________________________________________ The term partial discharge refers to the partial breakdown of insulation that develops in zones of highly concentrated electric fields. So, to prevent the breakdown occurs frequent observations must be done by utilising precise detection methods. The measurement of this kind of discharges is of importance because its existence is related to the aging of insulation in electric equipment. Partial discharge (PD) test is normally used to evaluate the insulation quality of high-voltage equipment. There are many PD detectors available in the market, and the detectors employ many techniques in measuring the PD. This paper presents a simplified and low cost device PD detection system with the use of the Rogowski coil (RC). The high frequency pulses due to the PD are detected by the RC. RC is developed for high frequency range from one MHz up to order of hundred MHz’s. An experimental analysis is performed to evaluate Rogowski coil performance and the effect of designed circuit on output waveform of RC sensor for PD detection. The experimental set-up is arranged in high voltage laboratory. The tests are carried out concerning measurement conditions such as on-line PD measuring systems. Input PD signal generated by pulse generator is passed through the centre of RC where the output of it is already connected to the designed circuit. The measurement is made by using oscilloscope to capture the output waveform. The circuit design is done to improve the RC output for better detection system as well as to obtain the signal that is replicates the input PD signal. From the experiment it is investigated that this RC detection method works linearly and with high sensitivity to the lowest input (5pC).
Contributor(s):
Puovin Murugaiah - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875007650
Language:
English
Subject Keywords:
discharge; breakdown; electric fields
First presented to the public:
6/1/2018
Original Publication Date:
8/7/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Electrical & Electronic Engineering
Citation:
Extents:
Number of Pages - 59
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-08-07 10:23:11.981
Date Last Updated
2019-01-07 11:24:32.9118
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Rogowski coil sensor for partial discharge Detection1 2018-08-07 10:23:11.981