Efficiency of using steel end caps in improving the post-fire flexural behavior of frp reinforced concrete beams / Rami J. A. Hamad

Efficiency of using steel end caps in improving the post-fire flexural behavior of frp reinforced concrete beams_Rami J. A. Hamad_A9_2017_MYMY
Penggunaan bar Polimer Bertetulang Gentian (FRP) sebagai alternatif kepada tetulang keluli tradisional dapat membantu mengatasi masalah ketahanlasakan dalam struktur konkrit bertetulang. Kelakuan struktur FRP-RC adalah memuaskan pada suhu yang rendah sahaja, oleh itu, penggunaan bahan-bahan FRP mudah terbakar dalam perdagangan, industri dan bangunan kediaman, di mana kemungkinan berlakunya kebakaran adalah agak tinggi, boleh menjadi berbahaya. Penyelidikan lanjut diperlukan untuk menilai dan meningkatkan prestasi struktur FRP-RC di bawah keadaan kebakaran. Dalam kajian ini, kesan suhu yang tinggi ke atas sifat mekanik bar FRP / Keluli, tingkah laku ikatan antara bar-bar FRP / keluli dan konkrit, dan tindak balas lenturan rasuk konkrit dengan pelbagai jenis bar tetulang FRP telah disiasat secara mendalam. Teknik tetopi-hujung keluli baru telah dicadangkan bertujuan untuk memperbaiki tambatan bar FRP yang tertanam dalam konkrit. Untuk itu, sampel dalam bentuk bar FRP / keluli, konkrit biasa, sampel tarik keluar dan rasuk (dengan dan tanpa tetopi-hujung keluli) telah disediakan dan kemudian diawet selama 28 hari serta seterusnya diuji sebelum dan selepas didedahkan kepada suhu tinggi sehingga 500°C. Konkrit dan FRP bar mengalami pengurangan ketara dalam sifat-sifat mekanikal mereka disebabkan oleh pendedahan kepada suhu yang tinggi. Kekuatan ikatan antara bar-bar FRP dan konkrit telah berkurangan apabila terdedah kepada suhu dalam julat 125-325°C, dengan pengurangan mencapai sehingga 85%. Pengurangan ini telah dipaparkan secara negatif dalam tingkah laku rasuk konkrit bertetulang FRP yang dipanaskan, di mana beban retak, kapasiti beban muktamad, kekakuan dan jumlah tenaga diserap telah berkurang sehingga 89%, 81%, 79%, dan 70%, masing-masing manakala pesongan pertengahan rentang dan indeks kemuluran telah meningkat dengan ketara sehingga masing-masing setinggi 50% dan 94%. Memasang tetopi hujung keluli di hujung bar FRP telah meningkatkan kekuatan ikatan mereka dengan konkrit sebelum dan selepas terdedah kepada suhu yang tinggi sehingga 325°C. Oleh itu, prestasi lenturan rasuk konkrit bertetulang FRP dengan tambatan tetopi hujung telah meningkat; beban retak, kapasiti beban muktamad, kekukuhan, pesongan pada beban muktamad, jumlah tenaga terserap dan indeks kemuluran masing-masing telah meningkat sehingga kira-kira (124%, 208%, 225%, 196%, and 453%) and (33%, 123%, 58%, 216% and 215%) sebelum dan selepas pemanasan sehingga 500 ° C, berbanding dengan rasuk kawalan tanpa tetopi-hujung keluli. Berdasarkan keputusan eksperimen, model analisis telah dicadangkan untuk meramalkan tingkah laku bahagian menaik hubungan ikatan-gelinciran antara bar FRP yang berbeza dan konkrit di bawah suhu yang tinggi. Satu kaedah teori juga tealah dicadangkan untuk meramalkan keupayaan beban muktamad teori rasuk konkrit bertetulang FRP. Ramalan kedua-dua model itu adalah bersetujuan dengan yang sangat baik dengan keputusan eksperimen. __________________________________________________________________________________ The use of Fiber Reinforced Polymer (FRP) bars as an alternative to traditional steel reinforcement helps overcoming durability problems in reinforced concrete structures. The behavior of FRP-RC structures is satisfactory at only low temperatures, hence the application of combustible FRP materials in commercial, industrial and residential buildings, where the possibility of fire occurrence is relatively high, can be dangerous. Further research to evaluate and enhance the performance of FRP-RC structures under fire conditions is required. In this study, the effect of high temperatures on the mechanical properties of FRP/Steel bars, bond behavior between FRP/Steel bars and concrete, and the flexural response of concrete beams with different types of FRP bar reinforcement was investigated in much details. A new steel-end-caps technique was proposed aiming to improve anchorage of embedded FRP bars in concrete. For that FRP/Steel bars, plain concrete, pullout and beam specimens (with and without steel end caps) were prepared and then cured for 28 days and later tested before and after subjected to elevated temperatures of up to 500°C. Concrete and FRP bars suffered significant reductions in their mechanical properties due to exposure to high temperatures. Bond strength between FRP bars and concrete had decreased upon exposure to temperature in the range of 125 to 325°C, with the reduction reaching as high as 85%. These reductions were reflected negatively in the behavior of heated FRP-RC beams hence cracking load, ultimate load capacity, stiffness and total absorbed energy were reduced by as high as 89%, 81%, 79%, and 70%, respectively whereas mid-span deflections and ductility indices were increased noticeably by as high as 50% and 94%, respectively. Attaching steel end caps to the ends of FRP bars had improved their bond strength with concrete before and after exposure to high temperatures of up to 325oC. Consequently, the flexural performance of FRP-RC beams with end-cap anchorage was improved where the cracking load, ultimate load capacity, stiffness, deflection at ultimate load, and total absorbed energy were increased to reach as high as (124%, 208%, 225%, 196%, and 453%) and (33%, 123%, 58%, 216% and 215%) before and after heating up to 500°C, respectively, compared with that of control beams without end anchorage. Based on the experimental results, an analytical model was proposed to predict the behavior of the ascending part of bondslip relation between the different FRP bars and concrete under high temperatures. Another theoretical method was also proposed to predict the theoretical ultimate load capacity of FRP-RC beams. The predictions of the two models were in an excellent agreement with the experimental results.
Contributor(s):
Hamad Rami J. A. - Author
Primary Item Type:
Thesis
Identifiers:
Accession Number : 875008404
Language:
English
Subject Keywords:
anchorage; relatively; reinforcement
Sponsor - Description:
Pusat pengajian Kejuruteraan Awam -
First presented to the public:
6/1/2017
Original Publication Date:
11/8/2019
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Civil Engineering
Citation:
Extents:
Number of Pages - 313