(For USM Staff/Student Only)

EngLib USM > Ω School of Electrical & Electronic Engineering >

Efficiency comparison of direct dc-ac power conversion system and conventional power conversion systems

Efficiency comparison of direct dc-ac power conversion system and conventional power conversion systems / Muhammad Najwan Hamidi
Populariti penyongsang bertingkat semakin berkembang terutamanya dalam aplikasi kuasa sederhana hingga tinggi. Hari ini, penyongsang DC-AC langsung seperti konfigurasi lata titi-H dan modular bertingkat (MML) titi separuh mendapat permintaan yang tinggi disebabkan kelebihan-kelebihan yang dimiliki berbanding konfigurasi konvensional seperti penyongsang apitan titik neutral dan kapasitor terbang. Fokus kertas kajian ini adalah pada perbandingan tahap kecekapan antara konfigurasi penyongsang DC-AC langsung dan penyongsang konvensional yang telah dinyatakan berdasarkan aplikasi sambungan grid. Ianya untuk memperolehi pengetahuan jelas tentang prestasi topologi-topologi yang dikaji. Penilaian kecekapan dilakukan sepenuhnya menggunakan pakej perisian simulasi PSIM. Untuk setiap topologi penyongsang, kuasa keluaran, voltan pautan DC, konfigurasi komponen semikonduktor dan kaedah penghasilan modulasi lebar nadi (PWM) telah dimalarkan bagi perbandingan yang adil. Dalam pengawalan kuasa, kawalan berasaskan kuadratur langsung (DQ) melalui kawalan kamiran berkadar (PI) bagi kuasa sebenar-kuasa reaktif (PQ) telah digunakan pada setiap topolgi yang dipilih. Bagi kaedah PWM pula, teknik anjakan tahap dalam fasa (IPDPWM) digunakan atas kemampuan penghasilan prestasi hormonik yang baik dengan komponen yang minima. Menerusi simulasi, penyongsang DC-AC langsung didapati mempunyai kecekapan yang lebih baik jika dibandingkan dengan penyongsang konvensional di mana kecekapan minimanya ialah 98.3 % dan mampu mencapai sehingga 99.1 %. Sebaliknya, kecekapan penyongsang DC-AC konvensional adalah pada julat 98.01 % ke 99.0 %. _______________________________________________________________________________________________________ Multilevel inverters are gaining popularity especially in medium to high power applications. Today, direct DC-AC inverters with the like of cascaded H-Bridge and modular multilevel (MML) Half-Bridge configuration are becoming much more accepted due to their vast advantages compared to older conventional inverter configurations such as neutral-point clamped and flying-capacitor inverter. This study focussed on efficiency comparison between these direct DC-AC inverter and conventional inverter topologies based on grid link application. The purpose is to get a clear overview of the performance of tested inverter topologies. The efficiency evaluation was fully performed by using PSIM simulation software package. For every selected inverter topology, the output power, DC link voltage, semiconductor devices configurations and pulse width modulation (PWM) method were kept constant for a fair comparison between them. In controlling the power, real power-reactive power (PQ), proportional-integral (PI) based direct-quadrature (DQ) control scheme was implemented in all selected topologies. As for the PWM method, In Phase Disposition Level Shifted PWM (IPDPWM) was used since it produces decent output harmonic performance with minimum components. From the simulations, it was observed that direct DC-AC inverters have better efficiency performance in overall compared to conventional DC-AC inverters where their minimum efficiencies were around 98.3 % and able to reached up to 99.1 %. On the other hand, conventional DC-AC inverters’ efficiencies ranged from 98.1 % to 99.0 %.
Contributor(s):
Muhammad Najwan Hamidi - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875007646
Language:
English
Subject Keywords:
Multilevel inverters; power applications; DC-AC
First presented to the public:
6/1/2018
Original Publication Date:
8/7/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Electrical & Electronic Engineering
Citation:
Extents:
Number of Pages - 121
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-08-07 09:58:27.391
Date Last Updated
2019-01-07 11:24:32.9118
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Efficiency comparison of direct dc-ac power conversion system and conventional power conversion systems1 2018-08-07 09:58:27.391