Kesan harmonik sistem kuasa ke atas transformer pengagihan dan rekabentuk baru dengan mengambil kira transformer faktor-k/Mohd Khairul Munir Jaafar

Kesan harmonik sistem kuasa ke atas transformer pengagihan dan rekabentuk baru dengan mengambil kira transformer faktor k_Mohd Khairul Munir Jaafar_E3_2006_NI
Peningkatan penggunaan beban tak lelurus dalam sistem kuasa elektrik menyebabkan kebimbangan terhadap jangka hayat transformer. Aplikasi sistem kadaran faktor K ini adalah untuk menentukan suatu transformer beroperasi dengan selamat apabila membekali gelombang arus tidak sinus. Maka laporan ini disediakan untuk mengkaji kesan-kesan harmonik pada transformer pengagihan daripada ujikaji yang telah dilakukan terhadap transformer satu fasa 250VA. Kesan harmonik pada transformer dikaji apabila beban lelurus dan beban tak lelurus dibekalkan kepada transformer. Terdapat dua jenis beban yang digunakan iaitu perintang tulin dan penerus. Ujikaji dilakukan bagi menyiasat kesan harmonik ke atas transformer seperti kehilangan, kecekapan dan kenaikan suhu transformer. Selain itu di dalam laporan ini juga dimuatkan dengan cara untuk mengurangkan kesan harmonik kepada transformer iaitu kaedah nyahkadaran. Dua kaedah nyahkadaran yang digunakan ialah dengan menggunakan kaedah nyahkadaran yang terdapat di dalam piawai IEEE C57.110-1986 dan menggunakan piawai BS 7841. Hasil ujikaji menunjukkan kehilangan semakin bertambah apabila jumlah herotan harmonik bertambah, kecekapan transformer menurun apabila jumlah herotan harmonik bertambah dan kenaikan suhu transformer bertambah apabila beban tak lelurus disambungkan kepada transformer berbanding beban lelurus. ______________________________________________________________________________________ Increases of non linear load on power system will reduce the transformer’s life expectancy. Distribution transformer manufacturers have been used the rating system called K-factor to ensure that the transformer can operate safely when suppying non-sinusoidal load current. This report was provided to show the effect of harmonic on the distribution transformer from the experiment done to single phase transformer 250VA. The effect of harmonic was investigated where linear and non linear load was connected to transformer. The load used in the experiment is pure resistance and rectifier. The experiments were done to investigate the effect of harmonic to the transformer such as losses, efficiency and temperature rise. Besides this report was included with the method used to reduce the harmonic effect to the transformer that is by using the derating method. Two derating method used is as recommended by standard of IEEE C57.110-1986 and BS 7821. The results show that there were increases in transformer losses, reduction of transformer efficiency and higher temperature rise compare to the linear load.
Contributor(s):
Mohd Khairul Munir Jaafar - Author
Primary Item Type:
Final Year Project
Language:
Bahasa Melayu
Subject Keywords:
transformer; power system ; temperature
First presented to the public:
5/1/2006
Original Publication Date:
5/6/2019
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Electrical & Electronic Engineering
Citation:
Extents:
Number of Pages - 96
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2019-05-07 10:46:46.147
Submitter:
Nor Hayati Ismail

All Versions

Thumbnail Name Version Created Date
Kesan harmonik sistem kuasa ke atas transformer pengagihan dan rekabentuk baru dengan mengambil kira transformer faktor-k/Mohd Khairul Munir Jaafar1 2019-05-07 10:46:46.147