(For USM Staff/Student Only)

EngLib USM > Ω School of Civil Engineering >

Assessment of seismic scenario-structure-based limit state criteria for 23-storey of rc high-rise building

Assessment of seismic scenario-structure-based limit state criteria for 23-storey of rc high-rise building / Puteri Nihal Che Kamahrudin
Isu-isu berkaitan untuk konkrit bertetulang bertingkat tinggi bangunan adalah berbeza scenario seismik seperti gempa bumi jarak jauh dan jarak dekat boleh menyebabkan perbezaan tahap dan lebih kompleks struktur gunung berapi senario yang berkaitan dengan kerosakan global. Objektif kajian ini adalah untuk menilai struktur gempa bumi senario untuk 23 tingkat bangunan konkrit bertetulang bertingkat tinggi berdasarkan perbezaan ukuran dan membangunkan lengkung kerapuhan dengan kriteria keadaan had yang berbeza. Dalam kajian ini, 23-tingkat, 83.95m tinggi, struktur konkrit bertetulang dipilih sebagai sebuah bangunan wakil sampel untuk menilai struktur gempa bumi senario. Enam rekod pergerakan tanah dipilih mewakili dua senario gempa bumi. Bangunan berasaskan senario seismik respon global meningkatkan mengukur keamatan gempa bumi telah dibuat menggunakan analisis dinamik tambahan. IDA lengkung dan anjakan antara tingkat adalah kajian berparameter. Prestasi struktur dan kerosakan ukuran RC bangunan tinggi telah dinilai dengan keadaan had prestasi berasaskan Prestasi Berdasarkan Rekabentuk Seismik (PBSD). ATC-43 (1998), mencadangkan empat tahap prestasi: Prestasi Operasi (OP), Penghunian Serta-Merta (IO), Keselamatan Hidup (LS) dan Pencegahan Kejatuhan (CP). Berdasarkan lengkung IDA, ia menunjukkan bahawa kesan gempa bumi jarak dekat mempunyai frekuensi tinggi yang memberi kesan pada awal keamatan ukuran pada bangunan runtuh berbanding kesan gempa bumi jarak jauh. Sementara itu, hasil anjakan antara tingkat menunjukkan bahawa kesan gempa bumi jarak dekat mempunyai kesan ketara yang besar ke arah kerosakan bangunan berbanding kesan gempa bumi jarak jauh. Mengenai kerapuhan lengkung, kesan gempa bumi jarak jauh mempunyai kesan yang sangat tinggi ke arah kerosakan struktur berbanding kesan gempa bumi jarak dekat. _______________________________________________________________________________________________________ Issues regarding to RC high-rise building is different seismic scenario such as near and far-field earthquake can result in difference levels and more complex of seismic scenario structure related to global damage. The objectives of this study are to evaluate the seismic scenario structure for 23-storey of RC high-rise building based on different damage measure and to develop the fragility curve with different limit state criteria. In this study, a 23-storey, 83.95m in height, RC structure is selected as a representative sample building to evaluate the seismic scenario structure. Six ground motions are selected representing two seismic scenarios. Seismic scenario-based building global response at increasing earthquake intensities measure is adopted using Incremental Dynamic Analysis. IDA curves and interstorey drift are the parametric study. The structural performance and damage measure of RC high-rise building were evaluated with the Performance Based Seismic Design (PBSD) limit state. ATC-43 (1998), proposed four performance levels: operational performance (OP), immediate occupancy (IO), life safety (LS), and collapse prevention (CP). Based on the IDA curves, it shows that near field effect has high frequency that gives impact at early intensities measure on building collapsed compared to far field effect. Meanwhile, interstorey drift result indicates that the near field effect has large effect towards the building damage compared to the far field effect. Regarding fragility curves, far field earthquake has larger effect towards the structural damage compared to the near field.
Contributor(s):
Puteri Nihal Che Kamahrudin - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875007637
Language:
English
Subject Keywords:
RC; high-rise building; earthquake
First presented to the public:
6/1/2018
Original Publication Date:
8/3/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Civil Engineering
Citation:
Extents:
Number of Pages - 75
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-08-03 12:01:04.144
Date Last Updated
2020-05-14 21:27:52.169
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Assessment of seismic scenario-structure-based limit state criteria for 23-storey of rc high-rise building1 2018-08-03 12:01:04.144