Creeping discharge behavior on wet and dry oil impregnated paper in transformer winding

Creeping discharge behavior on wet and dry oil impregnated paper in transformer winding / Nur Hidaya Mohamad Ariff
Pelepasan menjalar atau dikenali sebagai pelepasan permukaan adalah satu fenomena yang terhasil diatas permukaan penebat minyak pepejal. Pelepasan menjalar dicirikan sebagai corak seperti pokok oleh karbon dan karbon yang terhasil mencipta laluan pengalir yang tetap. Kelembapan didalam bahan penebat juga dikenali sebagai salah satu factor penhad utama kehidupan pengubah yang ditenggelami minyak. Selian itu, pelepasan ini juga memberi keputusan kegagalan dibawah keaadan operasi yang normal dan boleh megakibatkan mod kegagalan bagi system penebat. Oleh itu, objektif untuk projek ini adalah untuk membangunkan model sampel dalam dimensi kecil yang sesuai untuk memerhati perilaku pelepasan menjalar dan untuk menkaji pelepasan menjalar dalam dua keadaan berbeza kertas dirawat minyak (OIP) iaitu kertas basah dan kering. Ujian perlepasan menjalar diuji menggunakan kaedah elektrod jarum dan satah mendatar dengan sudut jarum 30˚ di atas permukaan kertas dirawat minyak. Terdapat tiga ujian dijalankan dalam project ini dengan perbezaan nilai voltan yang diberikan. Ujian pertama ialah dengan nilai voltan yand diberikan sebanyak 1kV/min untuk empat model sampel untuk mendapatkan satu diantara semua sampel yang paling sesuai bagi menkaji perilaku pelepasan menjalar. Setiap satu sampel model memberikan nilai voltan permulaan yang berbeza tetapi sampel yang menunjukkan situasi ‘flashover’ dalam jangka masa yang singkat dipilih sebagai model yang sesuai kerana bagi penebat cecair pepejal setiap pelepasan yang berlaku dianggap sebagai pelepasan menjalar termasuk sebahagian daripada pelepasan dan ‘flashover’. Ujian kedua ialah dengan nilai voltan yang diberikan mengikut kadar nilai perlepasan voltan permulaan untuk mengkaji perilaku perlepasan menjalar bagi keaadan kertas basah dan kering yang dirawat minyak seperti bilangan terjadinya keadaan ‘flashover’ atau pelepasan penuh, jarak tanda pengesan karbon diatas permukaan OIP dan masa pemulaan untuk penghasilan tanda pengesan karbon. Ujian yang terakhir ialah dengan nilai voltan yang diberikan sebanyak 10% daripada voltan permulaan untuk membandingkan perilaku perlepasan menjalar mereka. Konklusi yang dapar dibuat darpada perbandingan tersebut ialah tahap kelembapan berkadar songsang dengan voltan permulaan perlepasan menjalar dan masa permulaan bagi tanda pengesan karbon, dan berkadar terus dengan bilangan terjadinya ‘flashover’ dan jarak tanda pengesan karbon. _______________________________________________________________________________________________________ Creeping discharge or sometimes referred as surface discharge is a phenomenon that develop on the insulating oil / solid insulator interface. The creeping discharge is characterized by tree-like pattern of carbon and the carbon deposits gradually create permanent conductive path. Moisture in the cellulose insulation materials is known as one of the main life limiting factor of oil-immerse transformer. Moreover, this type of discharge result in failures under normal operating condition and can cause dangerous failure mode of the insulation system. Thus, the objectives of this project are to develop a model of sample in small dimension that suitable to observe the creeping discharge behavior and to study the creeping discharge behavior on two different condition of Oil Impregnated Paper (OIP) that is wet and dry. The creeping discharge behavior test was done using needle plane electrode with the needle angle is 30˚ on the OIP surface interface. There are three tests constructed in this project with different applied voltage. For the first test, 1kV/min was applied for four models of samples to find one of the suitable model to observed creeping discharge behavior. Each one of model give different creeping discharge inception voltage but the sample that shows the flashover event in the shortest time was chosen as the suitable model because for the solid liquid insulator any discharge that occur is considered as creeping discharge including partial discharge (PD) and flashover. For the second test, the creeping discharge inception voltage was applied to observe other creeping discharge behavior for wet and dry OIP such as the number of flashover, carbonized tracking mark and the initial time for carbonized tracking mark development. For the last test, 10% increment of creeping discharge inception voltage was applied to compare their behavior for both condition. Based on the comparison, it can be concluded that moisture level is inversely proportional to creeping discharge inception voltage and initial time of carbonized tracking mark development, and directly proportional to the number of flashover or discharge and the length of carbonized tracking mark on OIP interface.
Contributor(s):
Nur Hidaya Mohamad Ariff - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875006317
Language:
English
Subject Keywords:
Creeping discharge; phenomenon; insulating oil
First presented to the public:
6/1/2016
Original Publication Date:
6/6/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Electrical & Electronic Engineering
Citation:
Extents:
Number of Pages - 87
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-06-06 15:56:54.514
Date Last Updated
2019-01-07 11:24:32.9118
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Creeping discharge behavior on wet and dry oil impregnated paper in transformer winding1 2018-06-06 15:56:54.514