Cost comparison of seismic design for reinforced concrete building under Ranau earthquake / Nor Amelia Adha
Sempadan plat aktif boleh menyebabkan gempa bumi pada lokasi yang berhampirannya termasuk Malaysia. Pada 5 Jun 2015, gempa bumi telah berlaku di Ranau, Sabah dengan magnitud 6.0 skala Richter. Kerosakan serius pada bangunan tertentu telah berlaku akibat daripada kesan gempa bumi ini. Oleh itu, jurutera struktur memerlukan penyelesaian untuk mengatasi masalah ini daripada berlaku lagi. Anggaran kos bagi bangunan reka bentuk seismik adalah penting bagi jurutera untuk menganalisis dan mendapat pemahaman yang lebih baik tentangnya. Justeru itu, anggaran kos kepada sektor pembinaan kos sebagai persediaan awal untuk pelancaran Malaysia Annex untuk Piawai Malaysia dalam masa terdekat. Kajian ini memberi tumpuan kepada perbandingan kos antara reka bentuk seismik dan bukan seismik untuk tiga, enam dan sembilan tingkat dengan bangunan seragam dan tidak seragam. Analisis telah dijalankan dengan menggunakan perisian SAP 2000 dan direka bentuk berdasarkan Eurocode 2 untuk rasuk dan tiang. Keputusan menunjukkan bahawa bangunan reka bentuk seismik mempunyai kos yang paling tinggi dalam tan tetulang dan isipadu konkrit berbanding reka bentuk bukan seismik. Jumlah kos bangunan tiga tingkat yang mengalami beban seismik untuk bangunan seragam adalah 7.9 % lebih tinggi berbanding dengan reka bentuk bangunan bukan seismik. Jumlah kos bangunan tiga tingkat yang mengalami beban seismik untuk bangunan tidak seragam adalah 21.9% lebih tinggi berbanding dengan reka bentuk bangunan bukan seismik. Seterusnya, jumlah kos bangunan enam tingkat di yang mengalami beban seismik untuk bangunan seragam adalah 43.2 % lebih tinggi berbanding dengan reka bentuk bangunan bukan seismik. Jumlah kos bangunan enam tingkat di yang mengalami beban seismik untuk bangunan tidak seragam adalah 46.9 % lebih tinggi berbanding dengan reka bentuk bangunan bukan seismik. Selain itu, jumlah kos bangunan sembilan tingkat yang mengalami beban seismik untuk bangunan seragam adalah 13.1 % lebih tinggi berbanding dengan reka bentuk bangunan bukan seismik. Jumlah kos bangunan sembilan tingkat yang mengalami beban seismik untuk bangunan tidak seragam adalah 43.2 % lebih tinggi berbanding dengan reka bentuk bangunan bukan seismik. _______________________________________________________________________________________________________ Active plate boundaries can cause an earthquake to its nearest location including Malaysia. On 5th June 2015, an earthquake has occurred at Ranau, Sabah with magnitude of 6.0 Richter scale. Serious damages on certain building had occurred by the impact of this earthquake. Thus, structural engineers need solution to overcome this problem from happening again. The cost estimate for superstructure under seismic loading is important for engineers to analyze and have a better understanding on costing. Therefore, the cost estimation is important for Malaysia as preliminary information for construction player in preparation of the launch of Malaysia Annex to Standard Malaysia. This study focuses on comparison of cost between seismic and non-seismic design for three, six and nine storey with regular and irregular buildings. The analyses were carried out by using SAP 2000 software and calculated the beam and column design based on Eurocode 2. Results show that seismic design building has the higher cost in steel tonnage and concrete volume compared to the non-seismic design. The total cost of three storey under seismic design for regular building is 7.9 % higher compared to the non-seismic design building. The total cost of three storey under seismic design for irregular building is 21.9 % higher compared to the nonseismic design building. Next, the total cost of six storey under seismic design for regular building is 43.2 % higher compared to the non-seismic design building. The total cost of six storey under seismic design for irregular building is 46.9 % higher compared to the non-seismic design building. Besides that, the total cost of nine storey under seismic design for regular building is 13.1 % higher compared to the non-seismic design building. The total cost of nine storey under seismic design for irregular building is 43.2 % higher compared to the non-seismic design building.
Contributor(s):
Nor Amelia Adha - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875006834
Barcode : 00003106711
Language:
English
Subject Keywords:
plate boundaries; earthquake; seismic design
First presented to the public:
6/1/2017
Original Publication Date:
3/23/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Civil Engineering
Citation:
Extents:
Number of Pages - 87
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-03-23 11:21:27.771
Date Last Updated
2019-01-07 11:24:32.9118
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Cost comparison of seismic design for reinforced concrete building under Ranau earthquake1 2018-03-23 11:21:27.771