(For USM Staff/Student Only)

EngLib USM > @i* Standard >

MS 544 : Part 3 : 2001 Code of practice for structural use of timber: part 3 : permissible stress design of glued laminated timber

MS 544 : Part 3 : 2001 Code of practice for structural use of timber: part 3 : permissible stress design of glued laminated timber
Print version of this available at Library. To request please e-mail to adminpk@usm.my and include a copy of this record in your e-mail.
Glued laminated timber (glulam) should be manufactured in accordance with MS 758:2001 and Clause 4. All timber used for laminated members should be strength graded in accordance with BS 5756 or equivalent Malaysia Standard. NOTES: 1. The stresses given in this part of MS 544 apply only to timber graded in accordance with BS 5756 with respect to structural tropical hardwoods. Because this standard is primarily for solid structural timber, manufacturers of glued laminated timber may need to specify overriding requirements for wane, fissures and distortion. In deriving the recommended stress for timber, estimates of 5 % lower exclusion values of the strength and stiffness were used. Furthermore, the modulus of elasticity values no longer included element due to shear. 2. Grade and species for glulam that satisfy the requirement for strength classes are given in Table 1. Glulam strength properties may be determined from the strength class properties given in Table 2.
Primary Item Type:
Malaysian Standard
Identifiers:
Standard Number MS 544 : Part 3 : 2001
ICS 91.080.20
ISC ISC D - Building, Construction and Civil Engineering
Language:
English
Subject Keywords:
glued laminated timber; permissible design stress; grade stresses; end joints; strength class; compression; tension
First presented to the public:
10/29/2018
Original Publication Date:
5/22/2001
Previously Published By:
Department of Standards Malaysia
Place Of Publication:
Cyberjaya, Selangor
Citation:
Extents:
Number of Pages - 33
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-10-29 17:38:39.169
Date Last Updated
2019-01-07 11:24:16.6254
Submitter:
Badrul Hisham Ahmad Zuhdi

All Versions

Thumbnail Name Version Created Date
MS 544 : Part 3 : 2001 Code of practice for structural use of timber: part 3 : permissible stress design of glued laminated timber1 2018-10-29 17:38:39.169