Grounding system is important system to protect the overall system facility and to protect people from any hazardous condition. Bad and ineffective grounding system can cause damage of properties, badly injury and also the death. Due to importance of the grounding system, this thesis would like to discuss about detail about the grounding’s requirement and determine the grounding system for high rise building. There was a lot of factor that should be considered in designing a good grounding system, so in this project, it will decide the suitable grounding system for high rise building according the condition. Some important condition should be considered like lightning stoke threat and unwanted ground fault. So, lightning protection system and grounding system should be installing to high rise building. Beside that, it also must make sure that the grounding system reaches the requirement of NEC Article 250 and IEEE Standard _____________________________________________________________________ Sistem pembumian ialah sistem yang penting untuk melindungi semua peralatan dan melindungi manusia daripada keadaan bahaya. Sistem pembumian yang tidak baik atau kurang berkesan boleh menyebabkan kemusnahan harta benda, kecederaan dan juga boleh bawa maut. Memandangkan kepada kepentingan sistem pembumian, tesis ini akan membincangkan dengan lebih medalam tentang keperluan atau syarat-syarat suatu sistem pembumian yang baik dan seterusnya membuat keputusan kepada sistem pembumian untuk banguan yang tinggi. Terdapat pelbagai faktor yang perlu dipertimbangkan dalam rekabentuk sistem pembumian yang baik, oleh itu dalam projek ini akan membuat keputusan kepada sistem pembumian yang sesuai untuk banguanan yang tinggi mengikut keadaan. Keadaan yang penting perlu mengambil berat seperti kebahayaan kilat and arus bocor yang tidak diingin. Oleh itu ,Sistem jamin kilat dan sistem kebumian perlu dipasang kepada bangunan yang tinggi. Selain itu , juga mesti memastikan bahawa sistem pembumian mencapai kehendakan NEC Atikal 250 dan IEEE standard.
Contributor(s):
Ang, Pheak Huan - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875002438
Barcode : 00003068495
Language:
English
Subject Keywords:
Grounding system; considered like lightning stoke threat and unwanted ground fault.; grounding’s requirement and determine the grounding system for high rise building
First presented to the public:
1/5/2008
Original Publication Date:
2/7/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Electrical & Electronic Engineering
Citation:
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-02-07 16:29:42.904
Date Last Updated
2019-01-07 11:24:32.9118
Submitter:
Nor Hayati Ismail

All Versions

Thumbnail Name Version Created Date
Determination of grounding system fora high-rise building / Ang Pheak Huan_1 2018-02-07 16:29:42.904