(For USM Staff/Student Only)

EngLib USM > Ω School of Chemical Engineering >

Evaluation of protein immobilization on lateral flow nitrocellulose membrane via pulse mode measurement

Evaluation of protein immobilization on lateral flow nitrocellulose membrane via pulse mode measurement / Nabihah Mohamad Ketar@Mokhtar
Penyakit bawaan makanan dan minuman adalah penyakit yang disebabkan oleh bacteria yang terdapat di dalam makanan dan air yang tercemar. Setiap tahun, penyakit bawaan makanan dan minuman meningkat hari demi harai dimana sebahagian dari penyakit membawa kepada kematian. Oleh itu, kaedah yang mudah, sensitive dan spesifik untuk mengenalpasti bacteria yang menyebabkan penyakit tersebut adalah penting bagi memastikan praktis yang efektif untuk memastikan keselamatan makanan. Dengan prinsip tranduksi, biosensor telah digunakan dalam bidang mikrobiologi untuk mengenalpasti bakteria tersebut. Biosensor dengan kestabilan zon penangkap biomolekul yang tinggi dan kaedah elektrokimia yang tinggi telah dihasilkan. Prinsip biosensor yang dibuat adalah berdasarkan interaksi antara antigen dengan antibodi yang dimana penangkap reagen (biotinylated IgG) akan dikonjugat dengan zarah bermagnet polianilin bersaiz nano sebagai transduser elektrik untuk mengawal proses mengikat biomolekul yang spesifik yang akan dihasilkan oleh proses pempolimeran pengoksidaan dengan menggunakan monomer aniline dengan kehadiran ammonia sulfat sebagai agen pengoksidaan. Kesan kepekatan monomer aniline yang berbeza dan nisbah monomer kepada agen pengoksidaan yang berbeza semasa proses tersebut akan difokuskan untuk menghasilkan kestabilan biomolekul yang tinggi untuk bergerak kedalam zon penangkapan membrane plasma. Kepekatan aniline yang optimum dan nisbah aniline kepada ammonium persulphate yang optimum adalah 0.2M dan 1:3. Selepas dikonjugat, terdapat interaksi antara polyaniline dan Fe2O3 setelah dilihat dibawah Mikroskop Transmisi Elektron. Polianilin yang disintesis akan diintegrasikan dengan zarah nano bermagnet menerusi proses pempolimeran dengan nisbah 1: 0.6. Polianilin disintesis berdasarkan keadaan optimum dimana kepekatan monomer adalah 0.2 M dan nisbah monomer kepada agen pengoksidaan adalah 1:3. Struktur polianalin bercampur zarah nano yang bermagnet dianalisa oleh Mikroskop Transmisi Elektron dan cas zeta bagi setiap komponen (Fe2O3 dan PAni) dianalisa oleh Zetasizer nano. Kemudian, Fe2O3/PAni dicampurkan dengan glutaradehyde (GA). Pengubahsuaian Fe2O3/PAni-GA dengan molekul biotin melalui proses penjerapan fizikal telah dibuktikan dengan Zetasizer nano. Dalam menyediakan biosensor yang berasaskan polyaniline, biosensor tersebut dengan dimensi 60mm x 3mm terdiri daripada 3 membran plasma; pad perangkap, pad sampel dan pad penyerapan. Ketiga-tiga komponen ini disusun diatas sokongan belakang dan elektrod perak dilukis di kedua-dua sisi membran plasma nitroselulosa dengan jarak antara dua elektrod adalah 1mm. Terdapat dua proses garisan dalam kajian ini. Dalam kes pertama, membran plasma digariskan dengan protein BSA dengan menggunakan Isoflow reagent dispensing module dan diikuti dengan electrod perak. Untuk kes yang kedua, membran plasma digariskan dengan elektrod perak dahulu diikuti dengan protein BSA. Kedua-dua konfigurasi dilihat dibawah Mikroskop Cahaya. Ujian prestasi terakhir biosensor diukur dengam multimeter yang disambungkan kepada jalur biosensor. Konfigurasi terbaik iaitu konfigurasi dalam kes pertama ditakrif semasa kajian dan mencerminkan biosensor yang mempunyai kadar sensitiviti yang tinggi. _______________________________________________________________________________________________________ Foodborne and waterborne diseases are illness caused by bacteria that are present in contaminated food and water sources. Every year, foodborne and waterborne diseases are increasing day by day, where some of the diseases brings fatal. Thus, the realization of simple, sensitive and specific methods to detect foodborne pathogenic bacteria is crucial to implement effective practice to ensure food safety and security. As a principle of transduction, biosensor has been applied in the fields of microbiology to detect and quantify pathogenic bacteria. A biosensor with high stability of biomolecules capture zone and high sensitive electrochemical method has been developed. The working principle of the developed biosensor is based on the is antigen-antibody interaction where the capture reagent (biotinylated IgG) will be conjugated with polyaniline magnetite nanoparticles. Polyaniline, an electric signal transducer for the monitoring of the biospecific binding event, which will be synthesized based on the oxidative polymerization of aniline monomer in the presence of ammonium persulfate as oxidizing agent. The effect of different aniline concentration and volume ratio of aniline to ammonium persulphate used for oxidative polymerization is focused in order to produce high stability biomolecules to be immobilized onto the membrane capture zone. The optimum concentration and ratio of polyaniline is 0.2M and 1:3 respectively. Based on optimum concentration and ratio, polyaniline is conjugated with Fe2O3. After conjugation, it shows polyaniline which is in fibrous structure show some interaction with spherical size of Fe2O3 under TEM. The magnetic composite Fe2O3/PAni subsequently, conjugated with biotin molecules. The bio-modification of the Fe2O3/PAni-GA nanoparticles with biotin molecules by physical adsorption is confirmed by Zetasizer nano. In preparing polyaniline-based biosensor, the immunosensor used consists of the dimension of 60mm x 3mm that comprise of three disposable membrane pad; capture pad, sampling pad and absorption pad. All these three components assembled on backing support and silver electrodes are drawn along both sides of nitrocellulose membrane with the distance between two electode is at 1mm. There are two lining process in this study. In the first case, the capture pad (NC membrane) is lined with BSA first using automatic Isoflow reagent dispensing module and followed by silver paste . For the second case, the capture pad is lined with silver paste first followed by BSA. Both configuration are observed under Light Microscope. The final performance of biosensor signal is measured using multimeter which is connected to biosensor strip. The best configuration of biosensor which is in the first case shows higher resistance which reflect highest sensitivity of biosensor.
Contributor(s):
Nabihah Mohamad Ketar@Mokhtar - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875005204
Language:
English
Subject Keywords:
Foodborne; bacteria; contaminated
First presented to the public:
6/1/2013
Original Publication Date:
8/25/2020
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Chemical Engineering
Citation:
Extents:
Number of Pages - 106
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2020-08-25 10:35:36.055
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Evaluation of protein immobilization on lateral flow nitrocellulose membrane via pulse mode measurement1 2020-08-25 10:35:36.055