Investigation of harmonic distortion and losses in usm engineering campus / Nur Iryani Binti Baharudin

Investigation of harmonic distortion and losses in usm engineering campus_Nur Iryani Binti Baharudin_E3_2010_875003584_00003084275_NI
Tujuan utama projek ini adalah untuk menyiasat pengherotan harmonik dan kehilangan kuasa di Kampus Kejuruteraan USM. Pada kebiasaannya, beban yang tidak linear akan menyebabkan penjanaan harmonik yang boleh mengakibatkan kepanasan berlebihan terhadap peralatan elektrik. Di dalam projek ini, Pusat Pengajian Kejuruteraan Elektrik & Elektronik dan Pusat Komputer adalah tempat yang dipilih sebagai kajian disebabkan banyak penggunaan beban tidak linear berbanding tempat lain di kampus ini. Pengukuran paras harmonik telah dijalankan dan punca harmonik dapat dikenalpasti. Pengukuran paras arus harmonik dalam sistem pengagihan telah menjelaskan bahawa kebanyakan paras arus harmonik adalah lebih daripada 20% di mana lebih daripada piawai IEEE dan tidak dapat diterima. Keputusan menunjukkan paras arus harmonik tertinggi ialah 77.0% untuk talian kuasa ke Makmal Satelit di Pusat Pengajian Kejuruteraan Elektrik & Elektronik. Fenomena pengaliran arus neutral dalam sistem pengagihan empat wayar yang disebabkan oleh harmonik bernombor gandaan tiga dan sistem tiga fasa yang tidak seimbang telah disiasat. Pengiraan menunjukkan semua peratus nisbah antara arus neutral dan arus fasa adalah lebih daripada 50%. Peratus nisbah antara arus neutral dan arus fasa yang tertinggi adalah 121.49% untuk talian kuasa ke Makmal Pengajaran di Pusat Komputer. Kesan pengherotan harmonik kepada faktor kuasa dan kehilangan kuasa dalam sistem pengagihan telah diramalkan. Tiada peratus tetap untuk menunjukkan kehilangan kuasa yang berlebihan dan penurunan faktor kuasa yang disebabkan arus harmonik _____________________________________________________________________________________ The main purpose of this project is to investigate harmonic distortion and losses in the USM Engineering Campus. Often the nonlinearity of the load will results in the generation of harmonic that can cause overheating of the electrical equipment. In this project, the School of Electrical & Electronic Engineering and the Computer Centre are the selected places to be the case study due to many nonlinear load appliances compare to other places in this campus. The measurement of harmonic current level had been carried out and the source of harmonic had been identified. The measurement in the distribution system have illustrated that most of harmonic current levels are greater than 20% which are totally out of the IEEE standard and cannot be accepted. The results show that the highest harmonic current level recorded is 77.0% for power line to Satellite Lab at School of Electrical & Electronic Engineering. The phenomena of neutral current flow in four-wire distribution system due to triplen harmonic and unbalanced three phase system had been investigated. The calculation shows all the percentage of the ratio between neutral current and phase current are greater than 50%. The highest percentage of the ratio between neutral current and phase current is 121.49% for power line to the Instruction Lab at the Computer Centre. Effect of harmonic distortion to power factor and power loss in distribution system had been predicted. No fixed percentages to show the extra power loss and decrease in the power factor due to harmonic current.
Contributor(s):
Nur Iryani Binti Baharudin - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875003584
Barcode : 00003084275
Language:
English
Subject Keywords:
investigate harmonic distortion and losses in the USM Engineering Campus; nonlinearity of the load will results in the generation of harmonic that can cause overheating of the electrical equipment; phenomena of neutral current flow in four-wire distribution system due to triplen harmonic and unbalanced three phase system
First presented to the public:
4/1/2010
Original Publication Date:
3/19/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Electrical & Electronic Engineering
Citation:
Extents:
Number of Pages - 95
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-03-19 16:35:25.381
Date Last Updated
2019-01-07 11:24:32.9118
Submitter:
Nor Hayati Ismail

All Versions

Thumbnail Name Version Created Date
Investigation of harmonic distortion and losses in usm engineering campus / Nur Iryani Binti Baharudin1 2018-03-19 16:35:25.381