(For USM Staff/Student Only)

EngLib USM > @i* Standard > British Standard >

BS 7769-1.2:1994 : Electric cables — Calculation of the current rating — Part 1. Current rating equations (100% load factor) and calculation of losses — Section 1.2. Sheath eddy current loss factors for two circuits in flat formation

Printed version of this standard is available at Library. To request, please e-mail to referencepk@usm.my and include a copy of this record in your e-mail.
This section of IEC 287‑1 provides a method for calculating the eddy current losses in the metallic sheaths of single-core cables arranged as a three-phase double circuit in flat formation. The sheaths are bonded at one point or are cross-bonded so that there are no significant sheath circulating currents. Where metallic sheaths are bonded at both ends there are significant circulating currents which result in a lower current-carrying capacity. A method of calculating circulating current losses for double circuits is under consideration. The method provides coefficients which are applied as corrections to the loss factors for the sheaths of one isolated three-phase circuit. These corrections are negligible for cables where the parameter m is less than about 0,1 (m = ω/107Rs), which corresponds to a sheath longitudinal resistance higher than 314 µΩ/m at 50 Hz. Consequently the method should be used for most sizes of aluminium-sheathed cables, but is not required for lead-sheathed cables unless they are unusually large: The coefficients are provided in tabular form and have been computed from fundamental formulae for sheath losses, the evaluation of which calls for expertise in computer programming which might not be readily available in general commercial situations. The development of simplified formulae for some of the tabulated coefficients is under consideration. Losses for cables in a single circuit will be covered in IEC 287‑1‑1 (under consideration).
Contributor(s):
MJMS - Data Entry Person
Primary Item Type:
British Standard
Identifiers:
ICS  29.060.20 Cables
ISBN  0580232115
Language:
English
Subject Keywords:
Equations; Power losses; Mathematical calculations; Single-core cables; Rated current; Formulae (mathematics); Eddy currents; Cable sheaths; Double; Circuits; Insulated cables; Three-phase current; Electric cables; Power cables; Sheathed cables
First presented to the public:
2/22/2023
Original Publication Date:
7/15/1994
Previously Published By:
British Standards Institution
Place Of Publication:
London, United Kingdom
Citation:
Extents:
Number of Pages - 26
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2023-02-23 12:17:54.985
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
BS 7769-1.2:1994 : Electric cables — Calculation of the current rating — Part 1. Current rating equations (100% load factor) and calculation of losses — Section 1.2. Sheath eddy current loss factors for two circuits in flat formation1 2023-02-23 12:17:54.985