Secara asasnya terdapat dua jenis sistem tomografi iaitu tomografi bagi tujuan perubatan dan tomografi proses. Tomografi kemuatan elektrik (TKE) merupakan salah satu cabang di dalam tomografi proses yang diaplikasikan dalam sektor perindustrian pengimejan. Penggunaan TKE masih baru dan memerlukan kepakaran yang cukup untuk memajukan proses rekabentuk. TKE lebih kepada proses yang menggunakan komponan electromagnet iaitu kapasitor bagi tujuan menentukan nilai sesuatu parameter. Secara asasnya, terdapat beberapa jenis regim aliran yang wujud semasa aliran sebuah paip minyak, iaitu regim anulus, gelembung, strata, homogen penuh dan homogen kosong. Untuk projek ini, RNB yang digunakan ialah Multilayer Perception (MLP). Pengaturcaran Matlab versi 6.5 digunakan bagi proses menjanakan data TKE menggunakan pensimulasi TKE. Penggunaan nilai parameter pengesan TKE yang beza-beza mempengaruhi nilai data TKE yang diperolehi. Dalam proses ini, parameter R2 (lebar saluran paip) dan θ (lebar sudut elektrod) diubah nilainya dan dilihat perubahan data bacaan yang diperolehi. Julat nilai parameter R2 yang digunakan adalah 1.02 hingga 1.38 unit dan julat nilai θ yang digunakan adalah 5o hingga 24o. Purata data masukan ketinggian minyak yang diperolehi daripada proses pernormalan kemudiannya dibandingkan dengan nilai ketinggian sasaran dengan menggunakan fungsi RNB daripada program Matlab. Setiap perubahan ralat daripada proses perbandingan diplotkan didalam sebuah graf purata ralat melawan parameter R2 dan purata ralat melawan parameter θ. Graf ini bertujuan untuk _________________________________________________________________________________________ There are two types of tomography systems, medical tomography and process tomography. ECT is one of the branches of process tomography. ECT or Electrical Capacitance Tomography is one of the techniques to measure the internal spatial distribution of materials. This new and very detailed knowledge allows improved design of process equipment. ECT process is based on the electromagnet properties of components in the volume measurement. In this thesis, MATLAB is used to generate raw ECT dataset with using an ECT simulator. The variable value of an ECT design parameters affect the sensitivity of raw ECT dataset. In this project, the range of pipe thickness, R2 is uses 1.02 to 1.38 units and the range of electrode angle, θ is 5o to 24o. The mean of absolute error with comparison between oil height target and oil height ANN measurement is plot in two graphs, mean absolute error versus parameter R2 and mean absolute error versus parameter θ. The graphs show the changes in oil height estimation that occur when the ECT system parameters are changed.
Contributor(s):
Muhamed Sufian Hamzah - Author
Primary Item Type:
Final Year Project
Language:
English
Subject Keywords:
tomography; internal spatial; electromagnet
First presented to the public:
3/1/2005
Original Publication Date:
8/27/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Electrical & Electronic Engineering
Citation:
Extents:
Number of Pages - 50