(For USM Staff/Student Only)

EngLib USM > Ω School of Civil Engineering >

Comparison between pipe system and bioecods system by using storm water management model (swmm)

Comparison between pipe system and bioecods system by using storm water management model (swmm) / Chew Soo Kean
Pembangunan secara mendadak telah banyak mendatangkan masalah dalam pengurusan air larian ribut seperti banjir kilat di kawasan Bandar. Sistem perparitan konventional di mana akan mengalirkan air larian dengan secepat mungkin ke dalam sungai (pembuangan cepat). Sistem konventional ini berdasarkan manual Planning and Design Procedure by Department of Irrigation and Drainage (DID) pada 1975. Akan tetapi, sistem tradisional ini telah menyebabkan berlakunya banjir di hilir sungai. Dengan itu, manual baru telah diperkenalkan oleh DID pada 2001. Manual baru ini dikenali sebagai “Storm Water Management Manual (MSMA)”. Aplikasi Amalan Pengurusan Terbaik dan Kawalan di punca telah digunakan dalam sistem baru ini. Sistem baru ini telah diimplementasi oleh Universiti Sains Malaysia dengan kerjasama DID. Lokasi kajian tersebut terletak di Kampus Kejuruteraan, USM, Seberang Perai Selatan, Pulau Pinang, Malaysia. Untuk mengesan keberkesanan sistem baru, simulasi sistem paip (pembuangan secepat mungkin) dan sistem BIOECODS (Kawalan di punca) telah dijalankan dalam tesis ini. _______________________________________________________________________________________________________ Urbanization has led to problems in urban storm water management such as flash flood. A conventional drainage system has been designed to mitigate flash flood by transporting storm water runoff out of the catchments into river as fast as possible (rapid disposal). This conventional drainage system is based on manual “Planning and Design Procedure by Department of Irrigation and Drainage (DID)” in 1975. However this conventional system has led to the occurrence of flash flood at the downstream of the catchments. Therefore, a new manual has been introduced by DID Malaysia. This new manual is known as “Storm Water Management Manual (MSMA)” in 2001. “Best Management Practices (BMPs)” or control at source concept has been applied in this new manual to achieve zero development impact contribution. This new drainage has been implemented by Universiti Sains Malaysia in collaboration with DID. The site of study is located in USM Engineering Campus Seberang Perai Selatan District, Pulau Pinang, Malaysia. In order to verify the effectiveness of this new drainage system, simulation of pipe system (rapid disposal) and BIOECODS system (control at source) has been carried out as a comparison.
Contributor(s):
Chew Soo Kean - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875002057
Language:
English
Subject Keywords:
flood; drainage; mitigate
First presented to the public:
4/1/2005
Original Publication Date:
9/24/2020
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Civil Engineering
Citation:
Extents:
Number of Pages - 80
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2020-09-24 14:56:35.101
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Comparison between pipe system and bioecods system by using storm water management model (swmm)1 2020-09-24 14:56:35.101