Comparative study of bs8110 and eurocode 2 standards for design of a factory reinforced concrete flat slab

Comparative study of bs8110 and eurocode 2 standards for design of a factory reinforced concrete flat slab / Chong Hong Rui
Projek ini menyediakan latar belakang asas Kod Struktural Eropah dan aspek pengenalan terutamanya mengenai prinsip reka bentuk dan perbezaan dengan Kod British Standard. Projek ini juga mengaji dan membandingkan penggunaan BS 8110 dan EC 2 dalam reka bentuk slab rata konkrit bertetulang untuk menentukan perbezaan antara dua kod. Skop penyelidikan ini adalah merancang prinsip untuk reka bentuk papak dengan menggunakan Kaedah Rangka Setara. Pemuatan dan analisis diambil dari struktur papak yang dimuatkan dengan parit trek, dianalisis dan memberi ulasan reka bentuk. Bangunan yang digunakan untuk projek ini adalah bangunan kilang; Kilang Komponen Bangunan Precast Scandinavian Industrialized Building System (SIBS). Bangunan itu adalah bangunan satu tingkat yang terdiri daripada lantai dasar dengan bumbung dek keluli. Lantai dasar terdiri daripada kawasan pengeluaran dan penyimpanan. Bangunan ini adalah kira-kira 5m tinggi yang mempunyai pelan dimensi 110m x 46m. Kekuatan bar tetulang dan berat unit konkrit bertetulang Reka Bentuk British Standard sedikit kurang daripada reka bentuk EC 2. Perlindungan konkrit yang diperlukan untuk Reka Bentuk Eurocode 2 lebih daripada Reka Bentuk Standard British kerana lebih banyak ciri rintangan kebakaran. Kawasan bertetulang untuk kedua-dua jalur tengah dan jalur lajur serta sokongan jalur tengah dan jalur lajur British Standard Design adalah kurang daripada reka bentuk EC 2. Walaubagaimanapun, Reka Bentuk Standard British yang menggunakan wayar mesh BRC A10 perlu menyediakan lapisan kekuatan hasil menyebabkan kawasan bertetulang disediakan meningkat ke 569.9 mm2. Kos konkrit yang diperlukan untuk Reka Bentuk EC 2 adalah lebih tinggi daripada Reka Bentuk British Standard berdasarkan ketebalan lapisan konkrit yang telah direka. Kos bar tetulang keluli yang diperlukan untuk Reka Bentuk Eurocode 2 adalah lebih rendah daripada Reka Bentuk Standard British mengikut kawasan bar keluli yang direka bentuk. _______________________________________________________________________________________________________ This project provides some fundamental background of the European Structural Codes (Eurocodes) and some introductory aspects particularly on design principles and the differences with British Standard Codes brought about by the harmonised codes. This project also investigates and compares the use of BS 8110 and Eurocode 2 in the design of reinforced concrete flat slab to determine the differences between the two codes for this project. The scope of this research is designing principles for slab design by using the Equivalent Frame Method. The loading and analysis are taken from the slab structure that is loaded with track trench, analysed and detailed design results made based on the analysis results. The building adopted for this project is a factory building; the Scandinavian Industrialised Building System (SIBS) Precast Building Components Factory. The building is a one-storey building consisting of ground floor with steel deck roof. The ground floor consists of production and storage area. The building is about 5m high having an approximate plan dimension of 110m x 46m. The British Standard Design reinforcement bars strength and unit weight of reinforced concrete are slightly less than that of Eurocode 2 Design. The result of concrete cover needed for Eurocode 2 Design is more than that of British Standard Design due to more fire resistance characteristics. The reinforcement area for both span middle strip and column strip as well as support middle strip and column strip of British Standard Design is less than that of Eurocode 2 Design. However, the British Standard Design using BRC A10 wire mesh need to provide full yield strength lap length causing the reinforcement area provided increases to 569.9 mm2. The cost of concrete needed for Eurocode 2 Design is higher than that of British Standard Design based on the designed concrete cover thickness. Lastly, the cost of steel reinforcement bars needed for Eurocode 2 Design is lower than that of British Standard Design according to the designed steel reinforcement bars area provided.
Contributor(s):
Chong Hong Rui - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875007585
Language:
English
Subject Keywords:
European Structural Codes; design principles; British Standard Codes
First presented to the public:
6/1/2018
Original Publication Date:
8/3/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Civil Engineering
Citation:
Extents:
Number of Pages - 75
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-08-03 15:39:01.857
Date Last Updated
2020-05-15 15:03:20.395
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Comparative study of bs8110 and eurocode 2 standards for design of a factory reinforced concrete flat slab1 2018-08-03 15:39:01.857