BS 8103-1:1995 Structural design of low-rise buildings - Part 1. Code of practice for stability, site investigation, foundations and ground floor slabs for housing

Withdrawn
Printed version of this is available at library. To request, please e-mail to referencepk@usm.my and include a copy of this record in your e-mail.
This Part of BS 8103 gives recommendations for the structural design of low-rise housing and covers the stability of the structure, site investigation and foundations and ground floor slabs used in the construction. Foundations comprising strip footings or trench fill founded in normal ground are the only type described. Low-rise housing comprises detached, semi-detached and terraced houses and flats (with not more than four self-contained dwelling units per floor accessible from one staircase), of not more than three storeys above ground intended for domestic occupation and of traditional masonry construction with timber roofs and floors of timber or concrete. For the purposes of this standard additional habitable accommodation in the roof space constitutes a storey of the house. The recommendations also apply to certain single storey, non-residential buildings, e.g. domestic garages and annexes to residential buildings with a floor area not exceeding 36 m2 . This standard does not include the design of basements, but providing the basement is of one level only and is designed to provide a firm platform at ground level the provisions of this standard may apply to the superstructure. Proprietary housing systems, and houses of timber, steel or concrete framed construction are not covered by this standard. The structural design recommendations described in this standard are not specifically intended to cover other considerations such as fire resistance, thermal and sound insulation, resistance to damp penetration and durability. Reference should be made to other appropriate British Standards and statutory regulations and their supporting technical documents (e.g. BS 5628-3:1985 and the appropriate Approved Documents to the Building Regulations) for these and other matters. In using this standard the following limitations apply: a) roof: maximum clear span 12.0 m; b) floor: maximum clear span 6.0 m; c) design wind speed: not exceeding 44 m/s (see 5.3); d) no part of wall or roof higher than 15 m above lowest adjacent ground level; e) storey height: maximum 2.7 m; f) maximum clear length of a loadbearing wall between vertical lateral supports of 9.0 m; g) maximum length of any opening in loadbearing walls: 3.0 m; h) only strip footings or trench fill foundations in normal ground conditions (see 7.1). Where foundations other than those given in item h) have been designed by suitably qualified persons, the remainder of the building may be constructed in accordance with the relevant clauses of this standard.
Contributor(s):
MAR - Data Entry Person
Primary Item Type:
British Standard
Identifiers:
ISBN 0580233405
ICS 93.020 Earthworks. Excavations. Foundation construction. Underground works
ICS 91.040.30 Residential buildings
Language:
English
Subject Keywords:
Structural systems; Buildings; Housing; Shape; Structural members; Loadbearing walls; Walls; Dimensions; Design; Foundations; Concretes; Slab floors; Footings; Site investigations; Wind loading; Loading; Masonry work; Stability; Strip foundations; Structural design
First presented to the public:
12/29/2022
Original Publication Date:
9/15/1995
Previously Published By:
British Standards Institution
Place Of Publication:
London, United Kingdom
Citation:
Extents:
Number of Pages - 28
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2022-12-29 17:45:27.867
Submitter:
Muhamad Azmil Ramli

All Versions

Thumbnail Name Version Created Date
BS 8103-1:1995 Structural design of low-rise buildings - Part 1. Code of practice for stability, site investigation, foundations and ground floor slabs for housing1 2022-12-29 17:45:27.867