The study of the effect of feed pressure and flowrate on the LP GAS flare emission

The study of the effect of feed pressure and flowrate on the LP GAS flare emission / Dina Liyana Roshdin Murad
Sistem gas suar memainkan peranan utama dalam keselamatan pemasangan Minyak dan Gas iaitu dengan bertindak sebagai pengeluar untuk memberi bantuan tekanan kecemasan sekiranya proses terganggu. Pembakaran gas ini menghasilkan sejumlah tenaga yang banyak dan menyebabkan wabak penyakit, serta kemusnahan alam sekitar. Dalam kajian ini, terdapat keadaan operasi yang berbeza untuk menyukat gas yang dibakar serta hasilan pelepasan gas tersebut. Pada peringkat awal, penyelidikan ini adalah untuk mensimulasikan sistem suar LP gas melalui Aspen HYSYS, mengenal pasti kes-kes praktikal yang memberi kesan terhadap pelepasan gas suar, dan menentukan keadaan minimum atau mencapai kadar sifar pelepasan suar daripada 10 mmscfd. Terdapat empat kes praktikal yang telah dikenalpasti dan perlu dipertimbangkan dalam projek ini untuk mengurangkan kadar pembakaran gas. Kes pertama menggunakan pemampat sedia ada dan mempelbagaikan tekanan sedutan pemampat antara 5 dan 6 barg dengan jumlah kuasa pemampat adalah terhad sehingga 2280 kW. Pelepasan suar untuk kes ini ialah 7 mmscfd. Kes kedua menggunakan pemampat baru yang mana tekanan inlet mengalir masuk ke dalam sistem LP gas pada 5 dan 6 barg dengan membolehkan kadar aliran gas maksimum 31 mmscfd untuk mencapai kadar sifar pembakaran. Kes yang ketiga mengaplikasikan inlet pemisah LP 6 barg dan melakukan pengubahsuaian kecil pada kesesakan pemampat manakala jumlah maksimum kuasa elektrik dikekalkan pada 2280 kW. Pemeringkatan semula pemampat diperlukan dalam kes ini untuk disesuaikan dengan ubahsuai yang dibuat terhadap pemampat. Oleh itu, pelepasan suar 1 mmscfd dapat dicapai. Kes keempat melibatkan pengurangan tekanan pelepasan pada pemampat peringkat kedua iaitu dari 23 barg kepada 22 barg dengan jumlah kuasa elektrik pemampat yang sama. Oleh itu, pelepasan suar 6 mmscfd dapat diperolehi. Kes ketiga merupakan penyelesaian yang terbaik dalam mengurangkan kadar pembakaran gas tanpa memperkenalkan pemampat yang baru kerana ianya memberi kadar pembakaran yang sedikit berbanding dengan kes-kes yang lain kecuali kes kedua yang mana memberikan kadar pembakaran sifar apabaila memasang pemampat baru dengan kapasiti yang lebih besar. _______________________________________________________________________________________________________ Flare gas systems play a major role in the safety of Oil and Gas installations by serving as outlets for emergency pressure relief in case of process upsets. This gas flaring expends large amounts of energy, cause environmental degradation and disease. In the present work, there are different operating conditions to measure gas flared and its resulting emissions. The initial part of this research project is to simulate LP gas flare system in Aspen HYSYS, identify the practical cases affecting the flare gas emission, and determine the conditions for which minimum or zero flare emission can be achieved from the present 10 mmscfd. There are four practical cases being identified that are considered in this project in order to minimize the gas flaring rate. The first case uses the existing compressor and varying compressor suction pressure between 5 and 6 barg with total compressors power is limited up to 2280 kW. The flare emission for this case is 7 mmscfd. The second case uses a new compressor where the inlet pressure flow into LP gas system at 5 and 6 barg which allows a maximum gas flowrate of 31 mmscfd to achieve zero flaring rate. The third case is applying LP separator inlet of 6 barg and performing a minor modification on the compressor bottleneck while the compressor total electrical power is maintained at 2280 kW maximum. Compressor restaging is required for this case to suit with the modification made on the compressor. Thus, the flare emission of 1 mmscfd is achieved. The fourth case involves reduction of the discharge pressure at the second stage of the compressor from 23 barg to 22 barg with the same compressor total electrical power. Therefore, the flare emission of 6 mmscfd is achieved. The third case is the best solution in reducing gas flaring rate without introducing a new compressor because it gives the least flaring rate compared to other cases except for the second case which gives zero flaring rate when a new compressor with larger capacity is installed.
Contributor(s):
Dina Liyana Roshdin Murad - Author
Primary Item Type:
Final Year Project
Identifiers:
Barcode : 00003103380
Accession Number : 875005994
Language:
English
Subject Keywords:
Flare gas systems; safety of Oil and Gas installations; emergency pressure relief
First presented to the public:
6/1/2016
Original Publication Date:
5/21/2018
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Chemical Engineering
Citation:
Extents:
Number of Pages - 124
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2018-05-21 13:07:39.056
Date Last Updated
2019-01-07 11:24:32.9118
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
The study of the effect of feed pressure and flowrate on the LP GAS flare emission1 2018-05-21 13:07:39.056