Piling induced ground vibration observation

Piling induced ground vibration observation / Abdul Musawir Abdul Wahid
Gegaran akibat kerja pemacuan cerucuk mengundang pelbagai implikasi terhadap struktur bangunan dan juga keharmonian penduduk-penduduk sekeliling kawasan pemacuan cerucuk. Parameter gegaran menjadi lebih kritikal apabila kerja pemacuan dilakukan di kawasan bandar di mana struktur- struktur bangunan bertumpu di kawasan yang padat. Lima set data telah diperolehi dan dianalasis untuk menentukan parameterparameter kritikal di dalam gelombang gegaran akibat kerja pemacuan cerucuk. Datadata ini diperolehi melalui alat Blastronic Micro Meter yang telah diletakkan di lima kedudukan yang mempunyai jarak yang berbeza( 20m, 23m, 30m, 39m, dan 70m) daripada pusat sumber gegaran. Gegaran akibat pemacuan diuraikan kepada tiga bentuk gelembang iaitu gelombang radial, gelombang transverse and gelombang vertical. Perhubungan antara jenis-jenis gelombang ini dan jarak dinyatakan melalui graf-graf yang telah diplotkan. Data-data menunjukkan bahawa terdapat pengurangan dalam magnitud Peak Pariticle Velocity (PPV) dari titik punca gegaran ke suatu jarak dalam satu garisan lurus. Namun, nilai maksimum yang diperolehi untuk setiap jenis gelombang ialah, 9.2 mm/s untuk gelombang radial, 3.0 mm/s untuk gelombang transverse and 2.2 mm/s for gelombang vertical. Keamatan gegaran boleh ditunjukkan dengan merujuk analisis jumlah vektor gelombang. Hasil keputusan projek ini akan dapat membantu meningkatkan kefahaman tentang perkaitan antara parameter-parameter gegaran akibat kerja pemacuan cerucuk dari aspek magnitudnya. _______________________________________________________________________________________________________ Vibration due to piling work can cause numerous implications towards buildings and local residents around the area of the piling work. Its impact becomes more crucial if the piling work is done in compact urban locations whereby the buildings and area are densely populated. Five sets of data had been collected in order to determine which kind of waves carries the most significance in term of its magnitude. These data was attained using an instrument called Blastronic Micro Monitor which has been located at five different points of different lengths (20m, 23m, 30m, 39m and 70m) from the vibration source. The results generally show a decay of peak particle velocity (PPV) magnitude over distance in a straight line from the point of vibration source. However the maximum reading were, 9.2 mm/s for radial wave, 3.0 mm/s for transverse wave and 2.2 mm/s for vertical wave. The vibration induced by piling consists mainly of radial wave, transverse and vertical wave. The relationship between these waves and the length from where they were taken is analyzed. The intensity of the vibration is determined by analyzing the vector sum value of the wave. This thesis provides an understanding on how various signals from piling differ with each other in terms of their magnitude.
Contributor(s):
Abdul Musawir Abdul Wahid - Author
Primary Item Type:
Final Year Project
Identifiers:
Accession Number : 875002766
Language:
English
Subject Keywords:
Vibration; piling; implications
First presented to the public:
3/1/2006
Original Publication Date:
9/11/2020
Previously Published By:
Universiti Sains Malaysia
Place Of Publication:
School of Civil Engineering
Citation:
Extents:
Number of Pages - 89
License Grantor / Date Granted:
  / ( View License )
Date Deposited
2020-09-11 16:10:53.709
Submitter:
Mohd Jasnizam Mohd Salleh

All Versions

Thumbnail Name Version Created Date
Piling induced ground vibration observation1 2020-09-11 16:10:53.709